20mm US-A series galvo scan system

Item No.: SL-US20A2
Suitable for precision marking and welding.
Description

Sannylaser galvo scan system SL-US20A2 

the input aperture is 20mm (compatible with 1064nm 355nm 532nm 10.6um lenses ), uses digital driver, fully self-developed driver/ control algorithm/ motor. Strong interference resist performance, high speed, high precision, suitable for precision marking and welding.

Paremeters details:

 
 Model  SL-US20A2
 Input Beam Aperture (mm)  20
 Beam Displacement  (mm)  25.25
 Tracking Error (ms)  0.35
 Repeatability (µrad)  <2
 Offset Drift (µrad/K)  <12
 Gain Drift (ppm/K)  <50
 Long-term drift over 8 hours (mrad)  <0.15
 1% of full scale (ms)  0.7
 10% of full scale (ms)  2.4
 Positioning Speed (m/s)  6
 Typical Scan Angle (°)  ±12.5
 Gain Error (mrad)  <5
 Zero Offset (mrad)  <5
 Nonlinearity (%)  <0.4
 Power Requirements  ±15VDC, 3A
 Digital Interface  XY2-100
 Operation Temperature ()  25±10
 Weight (kg)  5
     


















 
   


Galvo Scanner Motor X

Galvo Scanner Motor Y